Search results for "Imaging phantom"
showing 10 items of 127 documents
Broadband Ultrahigh-Resolution Spectroscopy of Particle-Induced X Rays: Extending the Limits of Nondestructive Analysis
2016
Nondestructive analysis (NDA) based on x-ray emission is widely used, for example, in the semiconductor and concrete industries. Here, we demonstrate significant quantitative and qualitative improvements in broadband x-ray NDA by combining particle-induced emission with detection based on superconducting microcalorimeter arrays. We show that the technique offers great promise in the elemental analysis of thin-film and bulk samples, especially in the difficult cases where tens of different elements with nearly overlapping emission lines have to be identified down to trace concentrations. We demonstrate the efficiency and resolving capabilities by spectroscopy of several complex multielement …
K-nearest neighbor driving active contours to delineate biological tumor volumes
2019
Abstract An algorithm for tumor delineation in positron emission tomography (PET) is presented. Segmentation is achieved by a local active contour algorithm, integrated and optimized with the k-nearest neighbor (KNN) classification method, which takes advantage of the stratified k-fold cross-validation strategy. The proposed approach is evaluated considering the delineation of cancers located in different body districts (i.e. brain, head and neck, and lung), and considering different PET radioactive tracers. Data are pre-processed in order to be expressed in terms of standardized uptake value, the most widely used PET quantification index. The algorithm uses an initial, operator selected re…
Addressing the Occlusion Problem in Augmented Reality Environments with Phantom Hollow Objects
2018
Occlusion handling is essential to provide a seamless integration of virtual and real objects in AR applications. Different approaches have been presented with a variety of technologies, environment conditions and methods. Among these methods, 3D model-based occlusion approaches have been extensively used. However, these solutions could be too time-consuming in certain situations, since they must render all the occlusion objects even though they are invisible. For this reason, we propose an inverse 3D model-based solution for handling occlusions, designed for those AR applications in which virtual objects are placed inside a real object with holes or windows. With this restriction, the occl…
Synthesis, Stability and Relaxivity of TEEPO-Met: An Organic Radical as a Potential Tumour Targeting Contrast Agent for Magnetic Resonance Imaging
2018
Cancer is a widespread and life-threatening disease and its early-stage diagnosis is vital. One of the most effective, non-invasive tools in medical diagnostics is magnetic resonance imaging (MRI) with the aid of contrast agents. Contrast agents that are currently in clinical use contain metals, causing some restrictions in their use. Also, these contrast agents are mainly non-specific without any tissue targeting capabilities. Subsequently, the interest has notably increased in the research of organic, metal-free contrast agents. This study presents a new, stable organic radical, TEEPO-Met, where a radical moiety 2,2,6,6-tetraethylpiperidinoxide (TEEPO) is attached to an amino acid, methio…
Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study
2018
[EN] Anatomically based procedures to ablate atrial fibrillation (AF) are often successful in terminating paroxysmal AF. However, the ability to terminate persistent AF remains disappointing. New mechanistic approaches use multiple-electrode basket catheter mapping to localize and target AF drivers in the form of rotors but significant concerns remain about their accuracy. We aimed to evaluate how electrode-endocardium distance, far-field sources and inter-electrode distance affect the accuracy of localizing rotors. Sustained rotor activation of the atria was simulated numerically and mapped using a virtual basket catheter with varying electrode densities placed at different positions withi…
253. An accurate and operator independent method for biological tumour volume segmentation
2018
Purpose The aim of this paper is to develop an operator independent method for biological tumour volume (BTV) delineation from Positron Emission Tomography (PET) images. BTV delineation is challenging because of the low spatial resolution and high noise level in PET images. In addition, BTV varies substantially depending on the method used to segment. Manual delineation is widely-used, but it is strongly user dependent. Methods The proposed method starts with the automatic identification of the PET slice with maximum Standardized Uptake Value (SUV). Then, a user- independent mask is obtained by a rough pre-segmentation step and it is used to perform the local active contour segmentation on …
Efficacy of single-source rapid kV-switching dual-energy CT for characterization of non-uric acid renal stones: a prospective ex vivo study using ant…
2019
Purpose To investigate the accuracy of rapid kV-switching single-source dual-energy computed tomography (rsDECT) for prediction of classes of non-uric-acid stones. Materials and methods Non-uric-acid renal stones retrieved via percutaneous nephrolithotomy were prospectively collected between January 2017 and February 2018 in a single institution. Only stones >= 5 mm and with pure composition (i.e., >= 80% composed of one component) were included. Stone composition was determined using Fourier Transform Infrared Spectroscopy. The stones were scanned in 32-cm-wide anthropomorphic whole-body phantom using rsDECT. The effective atomic number (Zeff), the attenuation at 40 keV (HU40), 70 ke…
An In Vitro Phantom Study on the Role of the Bird-Beak Configuration in Endograft Infolding in the Aortic Arch.
2015
Purpose: To assess endograft infolding for excessive bird-beak configurations in the aortic arch in relation to hemodynamic variables by quantifying device displacement and rotation of oversized stent-grafts deployed in a phantom model. Methods: A patient-specific, compliant, phantom pulsatile flow model was reconstructed from a patient who presented with collapse of a Gore TAG thoracic endoprosthesis. Device infolding was measured under different flow and pressure conditions for 3 protrusion extensions (13, 19, and 24 mm) of the bird-beak configuration resulting from 2 TAG endografts with oversizing of 11% and 45%, respectively. Results: The bird-beak configuration with the greatest protr…
Abstract ID: 133 Fast and accurate 3D dose distribution computations using artificial neural networks
2017
In radiation therapy, the trade-off between accuracy and speed is the key of the algorithms used in Treatment Planning Systems (TPS). For photon beams, commercial solutions generally relies on analytic algorithms, biased Monte Carlo, or heavily parallelized Monte Carlo on Graphics Processing Units (GPU). Alternatively, we propose an algorithm using Artificial Neural Network (ANN) to compute the dose distributions resulting from ionizing radiations inside a phantom [1] , [2] . We present an evolution of this platform taking into account modulated field sizes and shapes, and various orientations of the beam to the phantom. Firstly, tomodensitometry-based phantoms are created to validate the d…
Registration-based Construction of a Whole-body Human Phantom Library for Anthropometric Modeling.
2020
Various computational human phantoms have been proposed in the past decades, but few of them include delicate anthropometric variations. In this study, we build a whole-body phantom library including 145 anthropometric parameters. This library is constructed by registration-based pipeline, which transfers a standard whole-body anatomy template to an anthropometry-adjustable body shape library (MakeHuman™). Therefore, internal anatomical structures are created for body shapes of different anthropometric parameters. Based on the constructed library, we can generate individualized whole-body phantoms according to given arbitrary anthropometric parameters. Moreover, the proposed phantom library…